skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: The Use of the Active Breathing Coordinator Throughout Radical Non-Small-Cell Lung Cancer (NSCLC) Radiotherapy

Journal Article · · International Journal of Radiation Oncology, Biology and Physics
 [1]; ; ; ; ;  [1]
  1. Royal Marsden NHS Foundation Trust and Institute of Cancer Research, Downs Road, Sutton, Surrey (United Kingdom)

Purpose: To assess feasibility and reproducibility of an Active Breathing Coordinator (ABC) used throughout radical radiotherapy for non-small-cell lung cancer, and compare lung dosimetric parameters between free-breathing and ABC plans. Methods and Materials: A total of 18 patients, recruited into an approved study, had free-breathing and ABC breath-hold treatment plans generated. Lung volume, the percentage volume of lung treated to a dose of {>=}20 Gy (V{sub 20}), and mean lung dose (MLD) were compared. Treatment (64 Gy in 32 fractions, 5 days/week) was delivered in breath-hold. Repeat breath-hold computed tomography scans were used to assess change in gross tumor volume (GTV) size and position. Setup error was also measured and potential GTV-planning target volume (PTV) margins calculated. Results: Seventeen of 18 patients completed radiotherapy using ABC daily. Intrafraction tumor position was consistent, but interfraction variation had mean (range) values of 5.1 (0-25), 3.6 (0-9.7), and 3.5 (0-16.6) mm in the superoinferior (SI), right-left (RL), and anteroposterior (AP) directions, respectively. Tumor moved partially outside the PTV in 5 patients. Mean reduction in GTV from planning to end of treatment was 25% (p = 0.003). Potentially required PTV margins were 18.1, 11.9, and 11.9 mm in SI, RL, and AP directions. ABC reduced V{sub 20} by 13% (p = 0.0001), V{sub 13} by 12% (p = 0.001), and MLD by 13% (p < 0.001) compared with free-breathing; lung volume increased by 41% (p < 0.001). Conclusions: Clinically significant movements of GTV were seen during radiotherapy for non-small-cell lung cancer using ABC. Image guidance is recommended with ABC. The use of ABC can reduce dose volume parameters determining lung toxicity, and might allow for equitoxic radiotherapy dose escalation.

OSTI ID:
21587742
Journal Information:
International Journal of Radiation Oncology, Biology and Physics, Vol. 81, Issue 2; Other Information: DOI: 10.1016/j.ijrobp.2010.05.038; PII: S0360-3016(10)00761-3; Copyright (c) 2011 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.; Country of input: International Atomic Energy Agency (IAEA); ISSN 0360-3016
Country of Publication:
United States
Language:
English