skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: PATHFINDER ATOMIC POWER PLANT. BUTTERFLY VALVE CAVITATION TEST

Technical Report ·
DOI:https://doi.org/10.2172/4717440· OSTI ID:4717440

Tests were made on butterfly vaives similar to those used in the discharge leg of each of the three external recirculation loops of the Pathfinder reactor in order to determine the critical values of a dimensionless cavitation number ( /occurred in pu ) used to specify the limits of operation for reactor valves, at incipient cavitation. The experimentally determined values of the cavitation number were used to determine the cavitation-free control range of the Pathfinder valves. The tests showed that both the undissolved and dissolved air content of the water caused cavitation to occur at higher values of sigma. It appeared that cavitation first occurred in the vortices downstream of the valve disk. A limiting cavitation condition was defined for the reactor butterfly valves. (M.C.G.)

Research Organization:
Allis-Chalmers Mfg. Co. Atomic Energy Div., Milwaukee
DOE Contract Number:
AT(11-1)-589
NSA Number:
NSA-17-022845
OSTI ID:
4717440
Report Number(s):
ACNP-62004
Resource Relation:
Other Information: For Northern States Power Co., Minneapolis and Central Utilities Atomic Power Assocites. Orig. Receipt Date: 31-DEC-63
Country of Publication:
United States
Language:
English

Similar Records

PATHFINDER ATOMIC POWER PLANT. BORON STAINLESS STEEL CONTROL RODS FOR PATHFINDER REACTOR. Final Summary Report
Technical Report · Fri Feb 15 00:00:00 EST 1963 · OSTI ID:4717440

PROTOTYPE RECIRCULATION PUMP TESTS. PATHFINDER ATOMIC POWER PLANT SUMMARY REPORT
Technical Report · Mon Jul 17 00:00:00 EDT 1961 · OSTI ID:4717440

Preventing cavitation in butterfly valves
Journal Article · Mon Mar 18 00:00:00 EST 1985 · Chem. Eng. (N.Y.); (United States) · OSTI ID:4717440